We are using cookies to implement functions like login, shopping cart or language selection for this website. Furthermore we use Google Analytics to create anonymized statistical reports of the usage which creates Cookies too. You will find more information in our privacy policy.
OK, I agree I do not want Google Analytics-Cookies
International Journal of Periodontics & Restorative Dentistry
Login:
username:

password:

Plattform:

Forgotten password?

Registration

Int J Periodontics Restorative Dent 38 (2018), No. 4     18. June 2018
Int J Periodontics Restorative Dent 38 (2018), No. 4  (18.06.2018)

Page 495-501, doi:10.11607/prd.3179, PubMed:29590222


Immediate Implant Placement in Single-Tooth Molar Extraction Sockets: A 1- to 6-Year Retrospective Clinical Study
Amato, Francesco / Polara, Giorgio
The aim of this study was to investigate the survival rate of implants immediately placed in fresh extraction sockets of molars in the maxilla and mandible with a single-stage procedure. A total of 102 patients were treated, and 107 implants (53 in the maxilla and 54 in the mandible) were placed in a fresh molar extraction socket and connected to a healing abutment. After a mean follow-up of 3 years (range: 1 to 6 years) 1 implant failed, for a cumulative success rate of 99.06% (98.11% for the mandible and 100% for the maxilla). The results of this study support placement of an implant immediately after the extraction of a molar, applying a single-stage procedure.